HEDH_TABOREK
This function calculates nucleate boiling heat transfer coefficient with the HEDH-Taborek correlation using saturation and critical pressure with either excess wall temperature or heat flux.
In general form:
h = f\left(P, P_c, \Delta T_e\right) \; \text{or} \; h = f\left(P, P_c, q\right)
It is used as a pressure-based empirical alternative for pool-boiling coefficient prediction.
Excel Usage
=HEDH_TABOREK(P, Pc, Te, q)
P(float, required): Saturation pressure of fluid (Pa).Pc(float, required): Critical pressure of fluid (Pa).Te(float, optional, default: null): Excess wall temperature (K).q(float, optional, default: null): Heat flux (W/m^2).
Returns (float): Heat transfer coefficient (W/m^2/K), or an error message if invalid.
Example 1: Reference example with excess temperature
Inputs:
| P | Pc | Te |
|---|---|---|
| 310300 | 2550000 | 16.2 |
Excel formula:
=HEDH_TABOREK(310300, 2550000, 16.2)
Expected output:
1397.27
Example 2: Reference case with heat flux
Inputs:
| P | Pc | q |
|---|---|---|
| 310300 | 2550000 | 25000 |
Excel formula:
=HEDH_TABOREK(310300, 2550000, 25000)
Expected output:
1497.9
Example 3: Lower pressure with excess temperature
Inputs:
| P | Pc | Te |
|---|---|---|
| 150000 | 2550000 | 10 |
Excel formula:
=HEDH_TABOREK(150000, 2550000, 10)
Expected output:
178.873
Example 4: Higher pressure with heat flux
Inputs:
| P | Pc | q |
|---|---|---|
| 600000 | 2550000 | 35000 |
Excel formula:
=HEDH_TABOREK(600000, 2550000, 35000)
Expected output:
2803.29
Python Code
Show Code
from ht.boiling_nucleic import HEDH_Taborek as ht_HEDH_Taborek
def HEDH_Taborek(P, Pc, Te=None, q=None):
"""
Compute nucleate boiling heat transfer coefficient using the HEDH-Taborek correlation.
See: https://ht.readthedocs.io/en/latest/ht.boiling_nucleic.html
This example function is provided as-is without any representation of accuracy.
Args:
P (float): Saturation pressure of fluid (Pa).
Pc (float): Critical pressure of fluid (Pa).
Te (float, optional): Excess wall temperature (K). Default is None.
q (float, optional): Heat flux (W/m^2). Default is None.
Returns:
float: Heat transfer coefficient (W/m^2/K), or an error message if invalid.
"""
try:
return ht_HEDH_Taborek(P=P, Pc=Pc, Te=Te, q=q)
except Exception as e:
return f"Error: {str(e)}"Online Calculator
Saturation pressure of fluid (Pa).
Critical pressure of fluid (Pa).
Excess wall temperature (K).
Heat flux (W/m^2).