KV_TO_K
Overview
Convert metric valve flow coefficient (Kv) to loss coefficient (K).
Excel Usage
=KV_TO_K(Kv, D)
Kv(float, required): Metric Kv valve flow coefficient [m^3/hr]D(float, required): Inside diameter of the valve [m]
Returns (float): Loss coefficient K [-]
Examples
Example 1: Basic Kv to K conversion
Inputs:
| Kv | D |
|---|---|
| 2.312 | 0.015 |
Excel formula:
=KV_TO_K(2.312, 0.015)
Expected output:
| Result |
|---|
| 15.1534 |
Example 2: Larger Kv value
Inputs:
| Kv | D |
|---|---|
| 10 | 0.025 |
Excel formula:
=KV_TO_K(10, 0.025)
Expected output:
| Result |
|---|
| 6.25 |
Example 3: Small valve diameter
Inputs:
| Kv | D |
|---|---|
| 1.5 | 0.01 |
Excel formula:
=KV_TO_K(1.5, 0.01)
Expected output:
| Result |
|---|
| 7.1111 |
Example 4: Large valve diameter
Inputs:
| Kv | D |
|---|---|
| 100 | 0.1 |
Excel formula:
=KV_TO_K(100, 0.1)
Expected output:
| Result |
|---|
| 16 |
Python Code
import micropip
await micropip.install(["fluids"])
from fluids.fittings import Kv_to_K as fluids_kv_to_k
def kv_to_k(Kv, D):
"""
Convert metric valve flow coefficient (Kv) to loss coefficient (K).
See: https://fluids.readthedocs.io/fluids.fittings.html#fluids.fittings.Kv_to_K
This example function is provided as-is without any representation of accuracy.
Args:
Kv (float): Metric Kv valve flow coefficient [m^3/hr]
D (float): Inside diameter of the valve [m]
Returns:
float: Loss coefficient K [-]
"""
try:
Kv = float(Kv)
D = float(D)
except (ValueError, TypeError):
return "Error: Kv and D must be numbers."
if Kv <= 0:
return "Error: Kv must be positive."
if D <= 0:
return "Error: D must be positive."
try:
result = fluids_kv_to_k(Kv=Kv, D=D)
return float(result)
except Exception as e:
return f"Error: {str(e)}"